Brookeld Engineering Labs., Inc. Page 1 Manual No. M98-350-J0912BROOKFIELD DIGITAL VISCOMETERMODEL DV-EOperating InstructionsManual No. M98-350
Brookeld Engineering Labs., Inc. Page 10 Manual No. M98-350-J0912 In case of emergency, turn off the instrument and then disconnect the el
Brookeld Engineering Labs., Inc. Page 11 Manual No. M98-350-J0912 I.8 Cleaning Make sure the instrument is in a decent working environment (d
Brookeld Engineering Labs., Inc. Page 12 Manual No. M98-350-J0912II. GETTING STARTED II.1 Power UpTurn the power switch (located on the rear
Brookeld Engineering Labs., Inc. Page 13 Manual No. M98-350-J0912Setting the SPEED/SPINDLE switch to the right position will allow the ope
Brookeld Engineering Labs., Inc. Page 14 Manual No. M98-350-J0912cP12RPM % S02(MOTOR ON)Figure II-5cP 12OFF % S02(MOTOR OFF)Figure II-6Note:
Brookeld Engineering Labs., Inc. Page 15 Manual No. M98-350-J0912 II.4 Autorange and CGS or SI Units Selection The AUTO RANGE key allows y
Brookeld Engineering Labs., Inc. Page 16 Manual No. M98-350-J0912cP 36010RPM % 9.0 S02Figure II-9 Negative % (Torque) will be displayed as
Brookeld Engineering Labs., Inc. Page 17 Manual No. M98-350-J0912 Appendix A - Viscosity RangesAppendix A - Viscosity RangesLV and RV,HA,HB Vis
Brookeld Engineering Labs., Inc. Page 18 Manual No. M98-350-J0912UL AdapterUL SpindleShear Rate (1/SEC)Viscosity (cP)LVDV-E RVDV-E HADV-E HBDV-
Brookeld Engineering Labs., Inc. Page 19 Manual No. M98-350-J0912 In taking viscosity measurements with the DV-E Viscometer, there are two con
Brookeld Engineering Labs., Inc. Page 2 Manual No. M98-350-J0912
Brookeld Engineering Labs., Inc. Page 20 Manual No. M98-350-J0912Appendix B - Variables in Viscosity Measurement As with any instrument measur
Brookeld Engineering Labs., Inc. Page 21 Manual No. M98-350-J0912 The shear rate of a given measurement is determined by: the rotational spee
Brookeld Engineering Labs., Inc. Page 22 Manual No. M98-350-J0912Appendix C - Spindle and Model Codes Appuuoijpoiendix C - Spindle and Model Co
Brookeld Engineering Labs., Inc. Page 23 Manual No. M98-350-J0912 VISCOMETER TORQUE CONSTANT MODEL CODE MODEL TK ON DV-E SCREEN LVDV-E
Brookeld Engineering Labs., Inc. Page 24 Manual No. M98-350-J0912Appendix D - Calibration Check ProceduresBrookeld’s accuracy statement for vi
Brookeld Engineering Labs., Inc. Page 25 Manual No. M98-350-J0912 Normal 25°C Standard Fluids Viscosity (cP) Viscosity (cP)High
Brookeld Engineering Labs., Inc. Page 26 Manual No. M98-350-J0912air bubbles beneath the disk by rst immersing the spindle at an angle, and th
Brookeld Engineering Labs., Inc. Page 27 Manual No. M98-350-J0912 When a Thermosel is used, the controller stabilizes the Thermo Container at
Brookeld Engineering Labs., Inc. Page 28 Manual No. M98-350-J0912 3) Attach the tube to the mounting channel. 4) Lower the tube into the wa
Brookeld Engineering Labs., Inc. Page 29 Manual No. M98-350-J0912 1) Calculate full scale viscosity range using the equation: Full Scale Vis
Brookeld Engineering Labs., Inc. Page 3 Manual No. M98-350-J0912I. INTRODUCTION ...
Brookeld Engineering Labs., Inc. Page 30 Manual No. M98-350-J0912Appendix E - Model A Laboratory Stand1425BROOKFIELDLABORATORYVISCOMETER11311VS
Brookeld Engineering Labs., Inc. Page 31 Manual No. M98-350-J0912Unpacking Check carefully to see that all the components are received with no
Brookeld Engineering Labs., Inc. Page 32 Manual No. M98-350-J0912Appendix F - The Brookeld Guardleg The guard leg was originally designed to
Brookeld Engineering Labs., Inc. Page 33 Manual No. M98-350-J0912 The guard leg is a part of the calibration check of the Brookeld LV and RV
Brookeld Engineering Labs., Inc. Page 34 Manual No. M98-350-J0912Appendix G - Fault Diagnosis and Troubeshooting Listed below are some of the
Brookeld Engineering Labs., Inc. Page 35 Manual No. M98-350-J0912Appendix H - Online Help and Other Resourceswww.brookeldengineering.com**The
Brookeld Engineering Labs., Inc. Page 36 Manual No. M98-350-J0912Appendix H - Warranty Repair and ServiceAppendix I - Warranty Repair and Servi
BROOKFIELD ENGINEERING LABORATORIES, INC. • 11 Commerce Blvd. • Middleboro, MA 02346 • Tel: 508-946-6200 or 800-628-8139 Fax: 508-946-6262 • www.brook
Brookeld Engineering Labs., Inc. Page 4 Manual No. M98-350-J0912
Brookeld Engineering Labs., Inc. Page 5 Manual No. M98-350-J0912I. INTRODUCTION I. INTRODUCTION The Brookeld DV-E Viscometer measures u
Brookeld Engineering Labs., Inc. Page 6 Manual No. M98-350-J0912Component Part Number QuantityDV-E Viscometer varies 1Model A laboratory st
Brookeld Engineering Labs., Inc. Page 7 Manual No. M98-350-J0912 I.2 Instrument Dimensions11 47/64”[29.8 cm]4 5/64”[10.4 cm]1 7/16”[3.7 cm]10
Brookeld Engineering Labs., Inc. Page 8 Manual No. M98-350-J0912 I.3 UtilitiesInput Voltage: 115 VAC or 230 VACInput Frequency: 50/60 HzPowe
Brookeld Engineering Labs., Inc. Page 9 Manual No. M98-350-J0912 I.5 Set-UpNote: “IQOQPQ”, a guideline document for installation, opera